Biomechanics of bipolar hip endoprostheses

WebJan 1, 1984 · Search life-sciences literature (39,397,469 articles, preprints and more) Search. Quick link: Coronavirus articles and preprints WebNov 1, 2005 · The results obtained are favorable for the bipolar hip endoprosthesis, and they can be related to the biomechanical differences between the three types of hip endoprostheses. Kinetic advantages of ...

Dynamic behavior of tripolar hip endoprostheses under …

WebMay 1, 2005 · To examine radiographically the component motion in a bipolar prosthesis and to determine whether the self-centering mechanism really works in vivo. 38 patients with 41 bipolar hip... WebThe implantation of a bipolar partial hip endoprosthesis is a treatment of choice for displaced medial femoral neck fracture. We present an experimental study which asses and compare biomechanical and clinical status through period before and after hip fracture and implantation of bipolar partial hip endoprosthesis. This study encompassed 75 ... ready set go pbs kids https://directedbyfilms.com

Biomechanical and clinical alterations of the hip joint following ...

WebMar 1, 1992 · The HEPFlEx-hip simulator (Hemi-EndoProsthesis Flexion Extension) was developed and the frictional coefficients produced by the different head materials and the … WebApr 1, 2005 · 38 patients with 41 bipolar hip endoprostheses (30 for coxarthrosis and 11 for osteonecrosis of femoral head) were included in this study. Two radiographs of each case were taken to evaluate the self-centering mechanism. The first anteroposterior radiograph of both hip joints was taken at the maximum abduction while the patient … WebThe bipolar endoprosthesis was designed to alleviate problems encountered with conventional hip endoprostheses. Recent designs have advocated the use of offset … how to take group policy backup

Bipolar hip hemiarthroplasty: What is it and what to expect

Category:Dynamic behavior of tripolar hip endoprostheses under physiological ...

Tags:Biomechanics of bipolar hip endoprostheses

Biomechanics of bipolar hip endoprostheses

Wear and performance of a tripolar total hip replacement

WebJan 1, 2008 · Only a few cases of bipolar hip prosthesis dislocation due to dissociation between the polyethylene and inner head of the prosthesis have been reported. We … WebAbstract. The bipolar endoprosthesis was designed to alleviate problems encountered with conventional hip endoprostheses. Recent designs have advocated the use of …

Biomechanics of bipolar hip endoprostheses

Did you know?

WebJun 22, 2024 · Summary. Bipolar hemiarthroplasty (BHA) is a surgical treatment for femoral neck fractures of the hip. An artificial joint with two bearings replaces the damaged joint. The bearings allow the head ... WebThe results obtained are favourable for the bipolar hip endoprosthesis, and they can be related to the biomechanical differences between both types of hip endoprosthesis. Some functional parameters of the hip-joint 3.3 years on average (range 2–8.6 years) after hip arthroplasty are compared with regard to two types of

WebHemiarthroplasty of the hip is commonly used to treat displaced femoral neck fractures in the elderly. 2,4-6,19 The choice of prosthesis type and fixation method used for this purpose is controversial. A bipolar hemiarthroplasty design has been used for this purpose for more than 30 years. 4,15,16 The proposed advantages of using the bipolar design rather than … WebJan 1, 2014 · Krein and Chao examined the dynamic of both concentric and eccentric bipolar hip endoprostheses under cyclic axial load. The theoretically and practically reported results were similar to those observed in this study. ... Biomechanics of bipolar hip endoprostheses. J Orthop Res, 2 (4) (1984), pp. 356-368. CrossRef View Record in …

WebThe results obtained are favorable for the bipolar hip endoprosthesis, and they can be related to the biomechanical differences between the three types of hip endoprostheses. Kinetic advantages of the BPEP as compared to the UPEP, can be explained by the BPEP's structure: two-level mobility and a thinner neck which delays impingement in the ... WebSep 1, 2010 · The implantation of a bipolar partial hip endoprosthesis is a treatment of choice for displaced medial femoral neck fracture. We present an experimental study …

WebApr 9, 2014 · Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Rostock, Germany ... For this type of total hip endoprostheses, an eccentric design of the outer bearing is assumed in order to provide a force-dependent self-centering mechanism and an improved joint stability against …

WebThe implantation of a bipolar partial hip endoprosthesis is a treatment of choice for displaced medial femoral neck fracture. We present an experimental study which asses … how to take group photo on ms teamsWebAug 1, 2024 · Biomechanics of bipolar hip endoprostheses. Article. Jan 1984; S W Krein; E.Y.S. Chao; The bipolar endoprosthesis was designed to alleviate problems encountered with conventional hip ... ready set go liveWebThe paper proposes a mechanical study of the self-centering mechanism of the bipolar prosthesis. This represents the fundamental principle of the bipolar construction, and relays on the offset between the inner and outer center of rotations of the bipolar head. In the paper, the kinematical aspects of the construction were recorded and explained by using … how to take gst certificate onlineWebSep 25, 2008 · The BHU bicentric bipolar endoprosthesis was designed at the department of orthopaedics, BHU, Varanasi, India in 2002. ... Krein SW, Chao EVS: Biomechanics of bipolar hip endoprosthesis. J Orthop Res. 1984, 2: 356-368. 10.1002/jor.1100020408. Article CAS PubMed Google Scholar ... ready set go maths junior infantsWebHemiarthroplasty of the hip using a low-friction bipolar endoprosthesis. Clin Orthop Relat Res 1983;86-92. ... Biomechanics of bipolar hip endoprostheses. J Orthop Res 1984;2:356-68. ASTM F561-97. Practice for Retrieval and Analysis of Implanted Medical Devices, and Associated Tissues. ASTM International, West Conshohocken, PA, 1997. how to take group fundsWebJun 22, 2024 · BHA provides a prosthesis with two joints, allowing most movements to occur at the inner bearing between the prosthetic head and the plastic liner of the bipolar … ready set go sermonWebIt was found that flexion, abduction and adduction were significantly higher in the BPEP endoprosthesis ( P < 0.05). The results obtained are favourable for the bipolar hip … ready set go meals hawkinsville ga